Product Description
Programmable 4-Channel DC Electronic Load Meter is a compact design and high functional electronic device. It is ideal to be used for the measurement of direct current load in varied systems and equipments. This type of load meter is widely demanded in industry of automotive, aerospace, fuel cells, electronics, etc for its exact measurement, low energy consumption, and simple maintenance. The Programmable 4-Channel DC Electronic Load Meter has soft PVC keypad to operate, LCD screen to display measured data and powder coated metal housing to resist corrosion, scratches and impact.
CP8212 |
Quantity of channel | 4 |
Channel parallel connection | Support channels parallel connection under any load mode CC/CV/CR/CP/LED |
Maximum input power of single channel | 100W |
Maximum input total power | 400W |
Channel input current | The low current measuring range: 0.05-2.5A | The high current measuring range: 2.5-10A |
Minimum operating voltage | 1V-2.5A | 5V-10A |
Input voltage | Low voltage measuring range: 1-50V | High voltage measuring range: 50-500V |
CC (constant current) load mode | Measuring range | 0.05A-2.5A | 2.5A-10A |
Resolution | 1mA | 10mA |
Precision | (1%+0.02%FS) |
CV (constant voltage) load mode | Measuring range | 1-50V | 50-500V |
Resolution | 0.012V | 0.12V |
Precision | (1%+0.02%FS) |
CR (constant resistance) load mode | Measuring range | 0.4-200 | 200-9.999k |
Resolution | 12bit | 12bit |
Precision | (1%+0.02%FS) |
CP (constant power) load mode | Measuring range | 100W |
Resolution | 50mW |
Precision | (1%+0.02%FS) |
LED simulation load mode | Measuring range | Vo | 1-50V | 50V-500V |
Io | 0.05-2A | 2A-10A |
Rd coefficients | 0.001-0.999 |
| Resolution | Vo | 0.012V | 0.12V |
| Io | 1mA | 10mA |
| | Rd coefficients | 0.001 |
| Precision | (1%+0.02%FS) |
Current measuring | Measuring range | 0.05A-2.5A | 2.5A-10A |
Resolution | 1mA | 10mA |
Precision | (1%+0.02%FS) | (1%+0.02%FS) |
Voltage measuring | Measuring range | 1-50V | 50-500V |
Resolution | 0.005V | 0.05V |
Precision | (1%+0.02%FS) |
Power measuring | Measuring range | 100W |
Resolution | 50mW |
Precision | (1%+0.02%FS) |
The dynamic testing mode | Cycle (T1&T2) | 100S-50S |
Resolution | 100S |
Precision | 2S+100ppm |
Current rate | 0.05mA-200mA/S | 0.5mA-750mA/S |
Flexible Multi-Channel PerformanceWith the ability to use all four channels independently or seamlessly in parallel, this electronic load meter offers unmatched testing versatility. Each channel can simulate different loading conditions, enabling complex evaluations or maximizing total current capacity, ideal for engineers and quality control teams.
Advanced Load Modes and Precision ControlsOperate under Constant Current (CC), Constant Voltage (CV), Constant Resistance (CR), or Constant Power (CP) load modes for highly tailored test scripts. A 7-inch TFT touchscreen provides intuitive control and data review, while high-precision shunt resistors ensure accurate measurements for professional-grade results.
Comprehensive Safety and ConnectivityThe system is equipped with over-voltage, over-current, over-power, over-temperature, and reverse polarity protections for worry-free operation. Interfaces including RS232, USB, and optional LAN enable seamless integration with test software and computer control, facilitating data management and automated processes.
FAQs of Programmable 4-Channel DC Electronic Load Meter:
Q: How can the 4-channel electronic load meter be used for simultaneous or parallel testing?
A: Each channel can function independently, allowing you to test four separate devices at once. Alternatively, channels can be connected in parallel to combine their capacity for higher current tests on a single device, providing flexibility for multi-mode setups.
Q: What storage options are available for test settings and how are they accessed?
A: The meter stores up to 50 preset data groups, enabling quick recall of complex test configurations. These can be accessed directly through the intuitive 7-inch TFT touchscreen, streamlining repeated procedures and improving workflow efficiency.
Q: When is it appropriate to use the different load modesCC, CV, CR, and CP?
A: Constant Current is ideal for battery discharge testing, Constant Voltage simulates load with a set voltage, Constant Resistance is used for resistive device testing, and Constant Power is suited to applications where fixed power draw is needed, such as power supply evaluation.
Q: Where can I monitor and control the electronic load meter remotely?
A: Remote monitoring and control are possible via the RS232, USB, or optional LAN interfaces. These connectivity options allow integration with PC software or automated test systems, supporting users in both lab and production settings.
Q: What safety protections are built into the device?
A: The load meter incorporates over-voltage, over-current, over-power, over-temperature, and reverse polarity protections to safeguard both the instrument and devices under test, ensuring safe operation in demanding environments.
Q: How does the intelligent fan cooling system benefit long-term usage?
A: The intelligent fan adjusts its speed automatically based on load and temperature, efficiently dissipating heat and extending the lifespan of internal components. This makes the unit more reliable during continuous or high-power testing sessions.